No you cannot see this on the sniffer. The ATTP command puts the device
into a continuous stream mode that is used for verifying RF
characteristics on a spectrum analyzer or other RF equipment.
Yes, use the Test Carrier (TC) AT command. To turn the test output on send the module “ATTC1” and to turn it off send it “ATTC0”. The test carrier will stay on until it is turned off or power cycled. Do not use this mode on battery powered devices as ...
Yes, it will sniff out any packets whether it comes from a coordinator or endpoint. The sniffer is a special diagnostic mode and thus is not operating as either a coordinator or endpoint itself.
The timestamp is the number of milliseconds from the previous message. The first message will always be 0, the second message will have the time from the first message, the third message shows the time from the second message, and so on.
The Voltage Sensor will generate events if the measured value rises above or falls below the configured thresholds. Byte 0: 7-4 Byte 0: 3-0 Byte 1 Byte 2 Byte 3 & 4 Protocol version (4 bits) Counter (4 bits) Message Type Code ...